Standard deviations of on-screen adjusted Sirscan readings were c

Standard deviations of on-screen adjusted Sirscan readings were comparable to the manual method (1.3 mm, 1.4 mm, and 1.0 mm, for S. aureus ATCC 29213, E. coli ATCC 25922, and P. aeruginosa ATCC 27853, respectively). The lower standard deviation of fully automated Sirscan readings was pronounced for certain antibiotics (Table 3): E.g. for trimethoprim-sulfamethoxazole and S. aureus ATCC 29213 (0.9 mm

versus 4.7 mm for fully automated Sirscan and manual readings, respectively) or for trimethoprim-sulfamethoxazole Cytoskeletal Signaling and nitrofurantoin in E. coli ATCC 25922 (0.4 and 0.5 mm versus 0.9 and 1.6 mm for fully automated Sirscan and manual readings, respectively). Table 3 Comparison of standard deviations

of measurements with calliper, the Sirscan system KPT-8602 price adaped on-screen by the human eye and the Sirscan fully automated mode S. aureus ATCC 29213                                           TOB AK CN CIP LEV P FOX E DA SXT RA average                 EUCAST QC range 20-26 18-24 19-25 21-27 23-29 12-18 24-30 23-29 23-29 29-32 30-36                     Sirscan fully automated                             INK1197 concentration                   Mean value 23.2 23.4 23.6 27.8 28.1 15.9 25.0 27.8 29.4 29.4 32.7 26.0                       Standard deviation 0.8 0.5 0.8 0.9 1.3 0.3 1.2 0.8 0.7 0.9 1.0 0.8*                   Sirscan on-screen adjusted                                               Mean value 24.7 25.5 25.2 Tryptophan synthase 27.8 29.5 15.8 26.1 30.4 29.9 29.8 33.6 27.1                       Standard deviation 1.2 0.7 1.4 1.7 1 0.4 0.9 2.2 3 1.3 0.7 1.3                   Calliper                                               Mean value 23.4 23.2 23.8 22.7 27.2 17.2 26.1 26.2 26.7 26.2 32.9 25.1                       Standard deviation 1 1.6 1.2 1.1 2 0.6 0.8 1.1 1.2 4.7 2.1 1.6*                   E. coli ATCC 25922                                           TOB AK CN NA NOR CIP LEV AM AMC TPZ CXM CAZ CTX CPD CRO FEP MEM ETP SXT NF average EUCAST QC range 18-26 19-26 19-26 22-28

28-35 30-40 29-37 16-22 18-24 21-27 20-26 23-29 25-31 23-28 29-35 31-37 28-34 29-36 23-29 17-23   Sirscan fully automated                                               Mean value 22.4 20.6 20.4 25.9 28.1 28.4 28.4 20.6 21.8 23.3 24.8 26.0 27.5 24.7 29.3 31.0 29.2 34.0 26.3 17.5 25.5     Standard deviation 1.1 0.8 0.5 0.8 0.6 1.0 0.7 0.9 0.6 0.4 0.4 0.0 0.5 0.5 0.7 0.7 0.9 0.8 0.4 0.5 0.7* Sirscan on-screen adjusted                                               Mean value 23.2 24.5 25.1 25.9 34 37.3 35.4 25.9 23.3 27.6 26.1 27.8 31.1 29.3 32.3 35 35.9 34.3 28.4 24.8 29.4     Standard deviation 1.5 1.3 1.4 1.3 2.4 1.6 1.5 1.8 1 1 1.2 1.2 1.9 1.2 1.3 1 1.2 1.2 1.4 1 1.4 Calliper                                               Mean value 22.4 24.4 23.3 27.6 31.1 34.1 31.5 22.3 25.1 25.7 24.8 25.5 28.5 27.6 30.2 33.7 23.9 34.3 27.3 17.4 27.0     Standard deviation 1.1 2.5 1.2 1.3 1 1.6 1.5 1.2 0.7 1.1 1.2 1 1.5 2.4 1.4 1.4 1.3 2.4 0.9 1.

Comments are closed.